UL 3289/3321/3173/3271/3344 XLPE CABLE

Application

These cables have excellent resistance to abrasion, deformation, cut-through and chemical attack. This wire is widely used in appliances, transformers, electrical heating, motors, ballast, lighting and cooking equipment. Suitable for use as Appliance Wiring Material (AWM), coil leads and as Class B IEEE 130°C Class Motor Leads. Economical replacement for silicone rubber/glass braid insulated wire and cable.

Technical Data

Standard : UL – Std. 758. Complies to CSA No. 22.2 210 and 127
Nominal Voltage : 600V
Test Voltage (Spark Test)
AWG 22 and 20 = 5kV
AWG 18 to 10 = 6kV
≥ AWG 8 = 7.5kV
Temperature Range : Flexible -5°C to +150°C. Fixed installation -50°C to +150°C
Temperature at Conductor : Max. UL : +150°C
Bending Radius : Approx. 5 x cable ø

Cable Construction

Annealed plain or tinned stranded copper conductor.
XLPE insulation according to UL- Std. 1581 Table 50.232, Complies to CSA No. 22.2 210 and 127.

Properties

PVC self – extinguishing and flame retardant, test method to FT 2

Cable Design Parameters

Kindly complete the part numbers for these cables by adding the suffix (in place of ‘z’) for the sheath colour required:
1 – black (RAL 9005), 3 – grey (RAL 7001).

AWGMetric Cross Section Area (Sq. mm)No. of Strands/Strand Dia. (mm)Max. DC Conductor Resistance for ABC @ 20°C (Ω/km)Max. DC Conductor Resistance for ATC @ 20°C (Ω/km)Insulation Thickness (mm)Nominal Cable Diameter (mm)
210.516/0.243.646.90.7622.4
190.7524/0.227.429.10.7622.6
18132/0.221.823.20.7622.8
161.530/0.2513.714.60.7623.1
142.550/0.258.628.960.7623.5
12456/0.35.435.640.7624.0
10684/0.33.4093.5460.7624.6
810140/0.32.1442.231.1436.1
616126/0.41.3481.4031.5247.9
425196/0.40.84810.8821.5249.1
235276/0.40.53350.55481.52410.7
150296/0.40.4230.43982.03212.8
Feb-0070360/0.50.2660.27662.03214.8
Mar-0095480/0.50.2110.21942.03216.2
Apr-00120.00608/0.50.16730.17222.03217.7

Kindly complete the part numbers for these cables by adding the suffix (in place of ‘xx’) for the insulation colour required:
01 – green, 02 – black, 03 – red, 04 – blue, 05 – yellow, 06 – green/yellow, 07 – white, 08 -violet, 09 – brown, 10 – orange, 11 – pink, 12 – grey, 13 – light blue
Kindly complete the part numbers by adding the suffix (in place of ‘c’) for the conductor type required:
0 = annealed bare copper (ABC), 1 = annealed tinned copper (ATC)

AWGMetric Cross Section Area (Sq. mm)No. of Strands/Strand Dia. (mm)
UL 3289UL 3321UL 3173UL 3271UL 3344
210.506090101xx9c06090116xx9c06090131xx9c06090146xx9c06090161xx9c
190.7506090102xx9c06090117xx9c06090132xx9c06090147xx9c06090162xx9c
18106090103xx9c06090118xx9c06090133xx9c06090148xx9c06090163xx9c
161.506090104xx9c06090119xx9c06090134xx9c06090149xx9c06090164xx9c
142.506090105xx9c06090120xx9c06090135xx9c06090150xx9c06090165xx9c
12406090106xx9c06090121xx9c06090136xx9c06090151xx9c06090166xx9c
10606090107xx9c06090122xx9c06090137xx9c06090152xx9c06090167xx9c
81006090108xx9c06090123xx9c06090138xx9c06090153xx9c06090168xx9c
61606090109xx9c06090124xx9c06090139xx9c06090154xx9c06090169xx9c
42506090110xx9c06090125xx9c06090140xx9c06090155xx9c06090170xx9c
23506090111xx9c06090126xx9c06090141xx9c06090156xx9c06090171xx9c
15006090112xx9c06090127xx9c06090142xx9c06090157xx9c06090172xx9c
2/07006090113xx9c06090128xx9c06090143xx9c06090158xx9c06090173xx9c
3/09506090114xx9c06090129xx9c06090144xx9c06090159xx9c06090174xx9c
4/0120.0006090115xx9c06090130xx9c06090145xx9c06090160xx9c06090175xx9c

Reviews

There are no reviews yet.

Be the first to review “UL 3289/3321/3173/3271/3344 XLPE CABLE”

Your email address will not be published. Required fields are marked *