LI2Y(ST)CY (TP)

Application

These data cables with twisted pairs are used for interference-free transmission of data and signals over longer distances. The high transmission rate are suitable for RS 422 and RS 485 interfaces. This cable forms an integral part of supervisory control and data acquisition (SCADA) systems.
These cables are suitable for fixed installations as well as for flexing applications, for free movement without forced motion and without tensile stress in dry and moist environment.

Technical Data

Standard: Based on VDE 0812
Voltage Grade (Not for power installation): Max. 250 V
Test Voltage: Core/core 2000 V. Core/screen 1000 V
Insulation Resistance: Min. 5000 GΩ x cm
Mutual Capacitance*: Max. 60 nF/km
Characteristic Impedance*: 100 Ω ±15
Cross-talk Attenuation: Upto 1 MHz min. 50 dB. Upto 10 MHz min. 40 dB
Inductance: Approx. 0.65 mH/km
Temperature Range: Flexing -5°C to +70°C.
Fixed installation -30°C to +70°C
Minimum Bending Radius: Flexing 15 x cable ø. Fixed installation 6 x cable ø

Cable Construction

Bare copper stranded 7 wire conductor Conductor make-up for
0.22 mm² = 7 x 0.20 mm
0.34 mm² = 7 x 0.25 mm 0.5 mm² = 7 x 0.30 mm
Conductor resistance (loop) at 20°C
0.22 mm² = 186 Ω/km (max.)
0.34 mm² = 115 Ω/km (max.)
0.5 mm² = 78.5 Ω/km (max.)
Metal coated copper is also offered on request.
Core insulation of PE (Polyethyelene).
Core colours as per DIN 47100 (Refer table no. 2-1)
Cores stranded in pair with optimal lay-length.
Pair stranded in layers with optimal lay-length.
Aluminium backed PETP foil over the laid up pairs.
Tinned copper braided screen, approx 85% coverage.
Special PVC outer sheath TM2, to EN 50363-4.1.
Sheath colour grey (RAL 7032).
Type …… Yv with reinforced black outer sheath suitable for outdoor application.
For underground burial, armoured version available on request.

Properties

PVC self-extinguishing and flame retardant according to EN 60332-1-2.
The twisted-pair lay-up prevents electrical unbalances within the cable and this thus effectively suppresses cross-talking effects.

*applicable upto 0.5 Sq. mm.

Cable Design Parameters

Part NumberNo. of Pairs & Nominal Cross Sectional Area(Sq.mm)Approx. Cable Diameter (mm)Approx. Copper Weight (kg/km)Approx. Cable Weight (kg/km)
Li2Y(St)CY (TP) Grey0505002210222 x 2 x 0.228.125.067
0505003210223 x 2 x 0.228.229.177
0505004210224 x 2 x 0.229.236.093
0505008210228 x 2 x 0.2212.060.7154
05050102102210x2x0.2213.271.8182
0505001210342 x 2 x 0.348.631.778
0505002210343 x 2 x 0.348.737.690
0505003210344 x 2 x 0.349.746.4110
0505004210348 x 2 x 0.3412.981.7185
05050082103410 x 2 x 0.3414.196.7219
0505002210502 x 2 x 0.59.138.989
0505003210503 x 2 x 0.59.248.1105
0505004210504 x 2 x 0.510.359.9129
0505008210508 x 2 x 0.513.7106.6221
05050102105010 x 2x 0.515.0127.9263
05050022l0752 x 2 x 0.759.750.1106
05050082l0753 x 2 x 0.759.963.5127
05050042l0754 x 2 x 0.7511.180.8158
0505008210758 x 2 x 0.7514.8145.2274
05050102107510 x 2 x 0.7516.3178.3331
0505002200012 x 2 x 110.460.2122
0505003200013 x 2 x 110.681.8152
0505004200014 x 2 x 111.9103.0189
0505008200018 x 2 x 115.9189.1333
05050102000110 x 2 x 117.5229.1401
Li2Y(St)CYv (TP)0506002210222 x 2 x 0.228.425.073
0506003210223 x 2 x 0.228.529.183
0506004210224 x 2 x 0.229.536.0100
0506008210228 x 2 x 0.2212.360.7163
05060102102210 x 2 x O.2213.571.8191
0506002210342 x 2 x 0.348.931.784
0506003210343x2x0.349.037.696
0506004210344 x 2 x 0.3410.046.4117
0506008210348x2x0.3413.281.7195
05060102103410 x 2 x 0.3414.496.7229
0506002210502 x 2 x 0.59.438.996
0506003210503 x 2 x 0.59.548.1112
0506004210504 x 2 x 0.510.659.9137
0506008210508 x 2 x 0.514.0106.6231
05060102105010 x 2 x 0.515.3127.9274
0506002210752 x 2 x 0.7510.050.1113
0506003210753 x 2 x 0.7510.263.5134
0506004210754 x 2 x 0.7511.480.8166
0506008210758 x 2 x 0.7515.1145.2285
05060102107510 x 2 x 0.7516.6178.3343
0506002200012 x 2 x 110.760.2129
0506003200013 x 2 x 110.981.8160
0506004200014 x 2 x 112.2103.0198
0506008200018 x 2 x 1162189.1345
05060102000110 x 2 x 117.8229.1414

Reviews

There are no reviews yet.

Be the first to review “LI2Y(ST)CY (TP)”