GXL

Application

These are standard wall insulated cables for general purpose application in automotive electric circuits of motorcycles and off-road vehicles.

Standard

In accordance to SAE J1128

Temperature Range (3000 Hrs)

-40°C to +125°C

Cable Construction

Soft annealed electrolytic copper ASTM B3
Cross-linked polyethylene (PE) with heat resistant properties according to SAE J1128

Packing

Available in 100 mtrs. coil. Longer length available in spools or wooden drums.

Special Properties

High temperature resistant and flame retardant
Provides higher reliability in heat resistance than conventional general wires due to emission bridging

Cable Design Parameter

SAE Conductor Size No.No. of StrandsMax. Strand Diameter
(mm)
Nominal Conductor Diameter
(mm)
Nominal Insulation Thickness
(mm)
Approx. Overall Diameter
(mm)
22*70.260.780.582.0
2070.320.960.582.2
20190.190.950.582.2
18160.261.220.582.4
18190.231.120.582.4
16190.291.450.582.7
14190.361.800.583.0
12190.452.250.663.6
10190.582.980.794.5
101040.252.900.794.5
8190.723.600.945.6
8500.453.670.945.6
6*370.725.101.097.3
6*1330.364.801.097.0

* Not as per SAE J1128

Reviews

There are no reviews yet.

Be the first to review “GXL”

Your email address will not be published. Required fields are marked *